Hirschmann DRAGON MACH4000-52G-L3A-MR Hloov

Kev Piav Qhia Luv:

Tag Nrho Gigabit Ethernet Backbone Switch nrog txog li 48x GE + 4x 2.5/10 GE ports, tsim modular, kiv cua unit ntsia, cov vaj huam sib luag dig muag rau daim npav kab thiab qhov chaw muab hluav taws xob suav nrog, cov yam ntxwv siab heev Layer 3 HiOS, multicast routing


Cov Lus Qhia Txog Khoom

Cov Cim Npe Khoom

Hnub Ua Lag Luam

 

Khoompiav qhia

Hom: DRAGON MACH4000-52G-L3A-MR
Lub Npe: DRAGON MACH4000-52G-L3A-MR
Kev piav qhia: Tag Nrho Gigabit Ethernet Backbone Switch nrog txog li 52x GE ports, tsim modular, kiv cua unit ntsia, cov vaj huam sib luag dig muag rau daim npav kab thiab qhov chaw muab hluav taws xob suav nrog, cov yam ntxwv siab heev Layer 3 HiOS, multicast routing
Cov Qauv Software: HiOS 09.0.06
Tus lej khoom: 942318003
Hom chaw nres nkoj thiab qhov ntau: Tag nrho cov chaw nres nkoj txog li 52, Chav yooj yim 4 qhov chaw nres nkoj ruaj khov: 4x GE SFP, Modular: 48x FE/GE chaw nres nkoj nthuav dav nrog plaub qhov chaw module media, 12x FE/GE chaw nres nkoj ib module

 

Ntau ntxiv Cov kev sib txuas lus

V.24 interface: 1 x RJ45 qhov (socket)
Qhov chaw rau daim npav SD: 1 x txuas tus kheej-configuration adapter ACA31 (SD)
USB interface: 1 x USB los txuas tus adapter teeb tsa tsis siv neeg ACA22-USB

 

Lub zogcov kev cai

Kev Ua Haujlwm Voltage:

PSU unit input: 100 - 240 V AC; qhov hloov pauv tuaj yeem ua haujlwm nrog 1 lossis 2 lub PSU hloov pauv tau (yuav tsum tau xaj cais)

Kev siv hluav taws xob:

80 W (xws li SFP transceivers + 1 PSU + Fan module)

 

Cov software

  

Kev Hloov:

Kev Kawm VLAN Ywj Pheej, Kev Laus Sai, Kev Nkag Mus Rau Chaw Nyob Unicast/Multicast Static, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, IP Ingress DiffServ Classification and Policing, IP Egress DiffServ Classification and Policing, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), Protocol-based VLAN, VLAN Unaware Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, MAC-based VLAN, IP subnet-based VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier per VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), Layer 2 Loop Protection
Kev Ua Dua Tshiab: HIPER-Ring (Ring Switch), HIPER-Ring hla Link Aggregation, Link Aggregation nrog LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), MRP hla Link Aggregation, Redundant Network Coupling, Sub Ring Manager, RSTP 802.1D-2004 (IEC62439-1), MSTP (802.1Q), RSTP Guards, VRRP, VRRP Tracking, HiVRRP (VRRP enhancements)
Kev Tswj: Kev Txhawb Nqa Duab Software Ob Chav, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, V.24, HTTP, HTTPS, Cov Ntxaib, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server
 Kev kuaj mob: Kev Tshawb Pom Qhov Teeb Meem Tsis Sib Haum Xeeb ntawm Chaw Nyob Tswj, Kev Ceeb Toom MAC, Kev Sib Txuas Lus, Kev Qhia Txog Qhov Xwm Txheej ntawm Lub Tshuab, TCPDump, LEDs, Syslog, Kev Sau Npe Mus Ib Txhis ntawm ACA, Kev Ceeb Toom Email, Kev Saib Xyuas Chaw Nres Nkoj nrog Kev Tua Tsis Siv Neeg, Kev Tshawb Pom Qhov Txuas Ntawm Qhov Txuas, Kev Tshawb Pom Qhov Ntau Dhau, Kev Tshawb Pom Qhov Tsis Sib Haum Xeeb ntawm Duplex, Kev Saib Xyuas Qhov Ceev Ntawm Qhov Txuas thiab Duplex, RMON (1,2,3,9), Kev Tshawb Pom Qhov Txuas 1:1, Kev Tshawb Pom Qhov Txuas 8:1, Kev Tshawb Pom Qhov Txuas N:1, RSPAN, SFLOW, Kev Tshawb Pom VLAN, Kev Tshawb Pom Qhov Txuas N:2, Cov Ntaub Ntawv System, Kev Tshawb Xyuas Tus Kheej ntawm Kev Pib Txias, Kev Tshawb Pom Qhov Txuas Tooj Liab, Kev Tswj Xyuas SFP, Kev Tshawb Xyuas Kev Teeb Tsa, Kev Hloov Pauv, Qhov Nta Kev Teeb Tsa Snapshot
 Kev teeb tsa: Tsis Siv Neeg Kho Kom Rov Qab Kho Kom Zoo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), BOOTP/DHCP Client nrog Auto-Configuration, DHCP Server: ib qho Port, DHCP Server: Pools ib VLAN, AutoConfiguration Adapter ACA31 (SD card), AutoConfiguration Adapter ACA21/22 (USB), HiDiscovery, DHCP Relay nrog Option 82, Command Line Interface (CLI), CLI Scripting, Full-featured MIB Support, Web-based Management, Context-sensitive Help
  

Kev Ruaj Ntseg:

Kev Ruaj Ntseg Chaw Nres Nkoj MAC, Kev Tswj Xyuas Kev Nkag Mus Rau Hauv Chaw Nres Nkoj nrog 802.1X, VLAN Qhua/tsis tau lees paub, Tus Neeg Pabcuam Kev Nkag Mus Rau Hauv Ib Lub Chaw Nres Nkoj (IAS), Kev Muab RADIUS VLAN Tso Cai, Kev Muab Txoj Cai RADIUS, Kev Pom Zoo Rau Ntau Tus Neeg Siv Khoom Ib Lub Chaw Nres Nkoj, Kev Hloov Chaw Pom Zoo MAC, DHCP Snooping, IP Source Guard, Kev Tshuaj Xyuas Dynamic ARP, Kev Tiv Thaiv Kev Tsis Kam Lees Paub Kev Pabcuam, LDAP, ACL Raws Li Ingress MAC, ACL Raws Li Egress MAC, ACL Raws Li Ingress IPv4, ACL Raws Li Lub Sijhawm, ACL Raws Li VLAN, ACL Raws Li Ingress VLAN, ACL Raws Li Egress VLAN, Kev Txwv Kev Nkag Mus Rau Kev Tswj Xyuas Uas Txwv Los Ntawm VLAN, Kev Qhia Txog Kev Ruaj Ntseg Ntawm Lub Tshuab, Txoj Kev Tshawb Xyuas, Kev Sau Npe Nkag Mus Rau Hauv CLI, Kev Tswj Xyuas Daim Ntawv Pov Thawj HTTPS, Kev Nkag Mus Rau Kev Tswj Xyuas Uas Txwv, Daim Ntawv Qhia Txog Kev Siv Uas Tsim Nyog, Txoj Cai Password Uas Kho Tau, Tus lej ntawm Kev Sim Nkag Mus Rau Hauv Chaw Nres Nkoj Uas Kho Tau, Kev Sau Npe Nkag Mus Rau Hauv SNMP, Ntau Qib Kev Tso Cai, Kev Tswj Xyuas Tus Neeg Siv Hauv Zos, Kev Pom Zoo Rau Chaw Nyob Ntawm Chaw Deb Ntawm RADIUS, Tus Account Neeg Siv Kev Xauv, Kev Hloov Lo Lus zais thaum nkag mus thawj zaug
Lub sijhawm synchronization: PTPv2 Lub Moos Pob Kaj Ob Kauj Ruam, PTPv2 Lub Moos Ciam Teb, Lub Moos Lub Sijhawm Tiag Tiag Buffered, SNTP Client, SNTP Server
Lwm yam: Kev Hla Cable Tes, Chaw Nres Nkoj Fais Fab

 

 

 Kev Taw Qhia:

Tus Pabcuam IP/UDP, Kev Tawm Tsam Ceev Tag Nrho, Port-based Router Interfaces, VLAN-based Router Interfaces, Loopback Interface, ICMP Filter, Net-directed Broadcasts, OSPFv2, RIP v1/v2, ICMP Router Discovery (IRDP), Equal Cost Multiple Path (ECMP), Static Unicast Routing, Proxy ARP, Static Route Tracking, IGMP v1/v2/v3, IGMP Proxy (Multicast Routing), DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)

Kev xa mus rau ntau lub channel: DVMRP, PIM-DM (RFC3973), PIM-SM / SSM (RFC4601)

 

Ib puag ncigtej yam kev mob

Kub ua haujlwm: 0-+60 °C
Kub cia/thauj: -40-+70 °C
Qhov av noo (tsis-condensing): 10-95%

 

Tshuab kev tsim kho

Qhov Loj (WxHxD): 480 hli x 88 hli x 445 hli
Kev Teeb: 19 "txee tswj hwm
Chav kawm tiv thaiv: IP20

 

 

Cov Kev Hloov Pauv

Khoom #

Hom

942318002

DRAGON MACH4000-52G-L3A-UR

 

 

Cov Qauv Muaj ntawm Hirschmann DRAGON MACH4000 Series

DRAGON MACH4000-48G+4X-L2A

DRAGON MACH4000-48G+4X-L3A-UR

DRAGON MACH4000-48G+4X-L3A-MR

DRAGON MACH4000-52G-L2A

DRAGON MACH4000-52G-L3A-UR

DRAGON MACH4000-52G-L3A-MR


  • Yav dhau los:
  • Tom ntej no:

  • Sau koj cov lus ntawm no thiab xa tuaj rau peb

    Cov khoom cuam tshuam

    • Hirschmann MACH102-8TP-R Hloov

      Hirschmann MACH102-8TP-R Hloov

      Kev Piav Qhia Luv Hirschmann MACH102-8TP-R yog 26 qhov chaw nres nkoj Fast Ethernet / Gigabit Ethernet Industrial Workgroup Switch (kho tau teeb tsa: 2 x GE, 8 x FE; ntawm Media Modules 16 x FE), tswj hwm, Software Layer 2 Professional, Store-and-Forward-Switching, fanless Design, redundant power supply. Kev Piav Qhia Cov Khoom Piav Qhia: 26 qhov chaw nres nkoj Fast Ethernet / Gigabit Ethernet Industrial Workgroup Sw ...

    • Hirschmann RS20-1600M2M2SDAUHC/HH Tsis Muaj Kev Tswj Xyuas Kev Lag Luam Ethernet Hloov

      Hirschmann RS20-1600M2M2SDAUHC/HH Kev Lag Luam Tsis Muaj Kev Tswj...

      Kev Taw Qhia RS20/30 Unmanaged Ethernet switches Hirschmann RS20-1600M2M2SDAUHC/HH Cov Qauv Ntsuas RS20-0800T1T1SDAUHC/HH RS20-0800M2M2SDAUHC/HH RS20-0800S2S2SDAUHC/HH RS20-1600M2M2SDAUHC/HH RS20-1600S2S2SDAUHC/HH RS30-0802O6O6SDAUHC/HH RS30-1602O6O6SDAUHC/HH RS20-0800S2T1SDAUHC RS20-1600T1T1SDAUHC RS20-2400T1T1SDAUHC

    • Hirschmann SPIDER II 8TX/2FX EEC Unmanaged Industrial Ethernet DIN Rail Mount Switch

      Hirschmann SPIDER II 8TX/2FX EEC Kev Lag Luam Tsis Muaj Kev Tswj...

      Cov lus piav qhia txog khoom Khoom: SPIDER II 8TX/2FX EEC Unmanaged 10-port Switch Cov lus piav qhia txog khoom Piav qhia: Nkag mus rau theem Industrial ETHERNET Rail-Switch, khw thiab xa mus rau pem hauv ntej switching hom, Ethernet (10 Mbit/s) thiab Fast-Ethernet (100 Mbit/s) Tus lej ntawm qhov chaw: 943958211 Hom chaw nres nkoj thiab ntau npaum li cas: 8 x 10/100BASE-TX, TP-cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity, 2 x 100BASE-FX, MM-cable, SC s...

    • Hirschmann GRS103-6TX/4C-2HV-2A Kev Hloov Kho Uas Tswj Tau

      Hirschmann GRS103-6TX/4C-2HV-2A Kev Hloov Kho Uas Tswj Tau

      Hnub Tim Muag Khoom Cov Lus Piav Qhia Txog Khoom Lub Npe: GRS103-6TX/4C-2HV-2A Software Version: HiOS 09.4.01 Hom chaw nres nkoj thiab qhov ntau: Tag nrho 26 Chaw nres nkoj, 4 x FE/GE TX/SFP thiab 6 x FE TX kho tau teeb tsa; ntawm Media Modules 16 x FE Ntau Qhov Sib Txuas Lus Fais fab mov/kev sib txuas lus: 2 x IEC ntsaws / 1 x plug-in terminal block, 2-pin, tso zis phau ntawv lossis hloov pauv tau (siab tshaj 1 A, 24 V DC bzw. 24 V AC) Kev Tswj Xyuas Hauv Zos thiab Kev Hloov Khoom Siv...

    • HIRSCHCHMANN RSPE35-24044O7T99-SCCZ999HHME2AXX.X.XX Rail Switch Power Enhanced Configurator

      HIRSCHCHMANN RSPE35-24044O7T99-SCCZ999HHME2AXX....

      Kev Taw Qhia Cov RSPE switches me me thiab ruaj khov heev muaj ib lub cuab yeej yooj yim nrog yim lub qhov rooj sib txuas thiab plaub lub qhov rooj sib txuas ua ke uas txhawb nqa Fast Ethernet lossis Gigabit Ethernet. Lub cuab yeej yooj yim - xaiv tau nrog HSR (High-Availability Seamless Redundancy) thiab PRP (Parallel Redundancy Protocol) cov txheej txheem redundancy tsis tu ncua, ntxiv rau lub sijhawm sib dhos raws li IEEE ...

    • Hirschmann MACH102-8TP Kev Tswj Xyuas Kev Lag Luam Ethernet Hloov

      Hirschmann MACH102-8TP Tswj Industrial Ether ...

      Kev piav qhia Cov khoom piav qhia Kev piav qhia: 26 qhov chaw nres nkoj Fast Ethernet / Gigabit Ethernet Industrial Workgroup Switch (kho tau teeb tsa: 2 x GE, 8 x FE; ntawm Media Modules 16 x FE), tswj hwm, Software Layer 2 Professional, Store-and-Forward-Switching, fanless Design Part Number: 943969001 Muaj: Hnub kawg xaj: Lub Kaum Ob Hlis 31st, 2023 Hom chaw nres nkoj thiab ntau npaum li cas: Txog li 26 Ethernet chaw nres nkoj, ntawm ntawd txog li 16 Fast-Ethernet chaw nres nkoj ntawm media modul ...