Hirschmann BRS40-00209999-STCZ99HHSES Hloov
Kev Piav Qhia Luv:
Lub Hirschmann BOBCAT Switch yog thawj lub uas siv tau los sib txuas lus tiag tiag siv TSN. Yuav kom txhawb nqa tau qhov kev xav tau sib txuas lus tiag tiag hauv kev lag luam, yuav tsum muaj lub Ethernet network backbone zoo. Cov compact managed switches no tso cai rau kev nthuav dav bandwidth los ntawm kev kho koj cov SFPs los ntawm 1 txog 2.5 Gigabit - tsis tas yuav hloov pauv rau lub tshuab.
Cov Khoom Qhia Txog Khoom
Cov Cim Npe Khoom
Hnub Ua Lag Luam
Khoom piav qhia
| Kev piav qhia | Kev Tswj Xyuas Kev Lag Luam rau DIN Rail, tsim tsis muaj kiv cua Txhua hom Gigabit |
| Cov Qauv Software | HiOS 09.6.00 |
| Hom chaw nres nkoj thiab qhov ntau | Tag nrho 20 Chaw nres nkoj: 20x 10/100/1000BASE TX / RJ45 |
Ntau ntxiv Cov kev sib txuas lus
| Kev sib txuas lus fais fab / kev taw qhia | 1 x plug-in terminal block, 6-pin |
| Cov tswv yim digital | 1 x plug-in terminal block, 2-pin |
| Kev Tswj Xyuas Hauv Zos thiab Kev Hloov Khoom Siv | USB-C |
| Twisted khub (TP) | 0 - 100 m |
Kev Sib Txuas Lus qhov loj - cascadibility
| Kab - / lub hnub qub topology | ib yam dab tsi |
Lub zog cov kev cai
| Kev Ua Haujlwm Voltage | 2 x 12 VDC ... 24 VDC |
| Kev siv hluav taws xob | 17 W |
| Lub zog tso zis hauv BTU (IT) / teev | 58 |
| Kev Hloov | Kev Kawm VLAN Ywj Pheej, Kev Laus Sai, Kev Nkag Chaw Nyob Unicast/Multicast Static, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier ib VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP) |
| Kev Rov Ua Dua | HIPER-Ring (Ring Switch), Link Aggregation nrog LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), Redundant Network Coupling, RSTP 802.1D-2004 (IEC62439-1), RSTP Guards |
| Kev Tswj Xyuas | Kev Txhawb Nqa Duab Software Ob Chav, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, Cov Ntxaib, SNMP v1/v2/v3, Telnet, Kev Tswj IPv6, OPC UA Server |
| Kev kuaj mob | Kev Tshawb Pom Qhov Teeb Meem Tsis Sib Haum Xeeb ntawm Chaw Nyob Tswj, Kev Ceeb Toom MAC, Kev Sib Txuas Lus, Kev Qhia Txog Qhov Xwm Txheej ntawm Lub Tshuab, TCPDump, LEDs, Syslog, Kev Sau Npe Mus Ib Txhis ntawm ACA, Kev Saib Xyuas Chaw Nres Nkoj nrog Kev Tua Tsis Siv Neeg, Kev Tshawb Pom Qhov Txuas Ntawm Qhov Txuas, Kev Tshawb Pom Qhov Ntau Dhau, Kev Tshawb Pom Qhov Tsis Sib Haum Xeeb ntawm Duplex, Kev Saib Xyuas Qhov Ceev Ntawm Qhov Txuas thiab Duplex, RMON (1,2,3,9), Kev Tshawb Pom Qhov Txuas 1:1, Kev Tshawb Pom Qhov Txuas 8:1, Kev Tshawb Pom Qhov Txuas N:1, Kev Tshawb Pom Qhov Txuas N:2, Cov Ntaub Ntawv Txog Lub System, Kev Tshawb Xyuas Tus Kheej ntawm Kev Pib Txias, Kev Tshawb Pom Qhov Txuas Tooj Liab, Kev Tswj Xyuas SFP, Kev Tshawb Xyuas Kev Teeb Tsa, Kev Hloov Pauv |
| Kev teeb tsa | Tsis Siv Neeg Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config ntawm lub server nyob deb thaum txuag, Tshem config tab sis khaws IP settings, BOOTP/DHCP Client nrog Auto-Configuration, DHCP Server: ib Port, DHCP Server: Pools ib VLAN, AutoConfiguration Adapter ACA21/22 (USB), HiDiscovery, USB-C Management support, Command Line Interface (CLI), CLI Scripting, CLI script handling over ENVM at boot, Full-featured MIB Support, Context-sensitive Help, HTML5 based Management |
| Kev Ruaj Ntseg | ISASecure CSA / IEC 62443-4-2 tau ntawv pov thawj, MAC-raws li Chaw Nres Nkoj Kev Ruaj Ntseg, Chaw Nres Nkoj Kev Nkag Mus Tswj nrog 802.1X, Qhua/tsis tau lees paub VLAN, Kev Sib Koom Ua Ke Authentication Server (IAS), RADIUS VLAN Assignment, Denial-of-Service Prevention, DoS Prevention Drop Counter, VLAN-raws li ACL, Ingress VLAN-raws li ACL, ACL yooj yim, Kev Nkag Mus Rau Kev Tswj Xyuas Txwv Los Ntawm VLAN, Kev Qhia Txog Kev Ruaj Ntseg Khoom Siv, Txoj Kev Tshawb Xyuas, CLI Logging, HTTPS Daim Ntawv Pov Thawj Kev Tswj Xyuas, Kev Nkag Mus Tswj Xyuas Txwv, Daim Ntawv Qhia Siv Tsim Nyog, Txoj Cai Password Configurable, Configurable Number of Login Attempts, SNMP Logging, Ntau Qib Privilege, Kev Tswj Xyuas Tus Neeg Siv Hauv Zos, Kev Pom Zoo Chaw Deb Ntawm RADIUS, Kev Xauv Tus Neeg Siv Account, Hloov Password Thaum Nkag Mus Thawj Zaug |
| Kev sib dhos sijhawm | PTPv2 Lub Moos Pob Kaj Ob Kauj Ruam, PTPv2 Lub Moos Ciam Teb, BC nrog Txog Li 8 Sync / s, 802.1AS, Buffered Real Time Clock, SNTP Client, SNTP Server |
| Cov Ntaub Ntawv Kev Lag Luam | EtherNet/IP Protocol, IEC61850 Protocol (MMS Server, Switch Model), Modbus TCP, PROFINET Protocol |
| Lwm yam | Kev Tswj Xyuas IO Digital, Kev Hla Cable Manual, Chaw Nres Nkoj Fais Fab |
Cov xwm txheej ib puag ncig
| MTBF (Telecordia SR-332 Qhov Teeb Meem 3) @ 25°C | 1 639 262 teev |
| Kub ua haujlwm | 0-+60 |
| Kub cia / thauj mus los | -40-+70 °C |
| Qhov av noo (tsis-condensing) | 1- 95% |
Kev tsim kho tshuab
| Qhov Loj (WxHxD) | 109 hli x 138 hli x 115 hli |
| Qhov hnyav | 1060 g |
| Tsev nyob | PC-ABS |
| Kev Teeb Tsa | DIN Rail |
| Chav kawm tiv thaiv | IP30 |
Cov Qauv Muaj ntawm Hirschmann BRS40 BOBCAT Series
BRS40-0012OOOO-STCZ99HHSESXX.X.XX
BRS40-0008OOOO-STCZ99HHSESXX.X.XX
BRS40-00169999-STCZ99HHSESXX.X.XX
BRS40-0020OOOO-STCZ99HHSESXX.X.XX
BRS40-00209999-STCZ99HHSESXX.X.XX
BRS40-00249999-STCZ99HHSESXX.X.XX
BRS40-0024OOOO-STCZ99HHSESXX.X.XX
Cov khoom cuam tshuam
-
Hirschmann RS20-0800M4M4SDAE Kev Hloov Chaw Tswj Xyuas
Kev Piav Qhia Khoom: RS20-0800M4M4SDAE Configurator: RS20-0800M4M4SDAE Kev Piav Qhia Khoom Kev Piav Qhia Tswj Fast-Ethernet-Switch rau DIN rail khw-thiab-mus tom ntej-switching, tsim tsis muaj kiv cua; Software Layer 2 Enhanced Part Number 943434017 Hom chaw nres nkoj thiab ntau npaum li cas 8 chaw nres nkoj tag nrho: 6 x tus qauv 10/100 BASE TX, RJ45; Uplink 1: 1 x 100BASE-FX, MM-ST; Uplink 2: 1 x 100BASE-...
-
Hirschmann MS20-1600SAAEHHXX.X. Kev Tswj Xyuas Modular...
Cov lus piav qhia txog khoom Hom MS20-1600SAAE Kev piav qhia Modular Fast Ethernet Industrial Switch rau DIN Rail, Fanless design, Software Layer 2 Enhanced Part Number 943435003 Hom chaw nres nkoj thiab ntau npaum li cas Fast Ethernet ports tag nrho: 16 Ntau Interfaces V.24 interface 1 x RJ11 socket USB interface 1 x USB rau conn...
-
Hirschmann SPIDER-PL-20-16T1999999TY9HHHV Hloov
Cov lus piav qhia txog khoom Cov lus piav qhia txog khoom Kev piav qhia Tsis tswj hwm, Kev lag luam ETHERNET Rail Switch, tsim tsis muaj kiv cua, khaws cia thiab hloov mus tom ntej hom, USB interface rau kev teeb tsa, Fast Ethernet, Fast Ethernet Port hom thiab ntau npaum li cas 16 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity Ntau Interface...
-
Hirschmann GRS103-6TX/4C-2HV-2S Kev Hloov Kho Uas Tswj Tau
Hnub Tim Muag Khoom Cov Lus Piav Qhia Txog Khoom Lub Npe: GRS103-6TX/4C-2HV-2S Software Version: HiOS 09.4.01 Hom Chaw Nres thiab Qhov Ntau: Tag Nrho 26 Chaw Nres, 4 x FE/GE TX/SFP thiab 6 x FE TX kho tau teeb tsa; ntawm Media Modules 16 x FE Ntau Qhov Sib Txuas Lus Fais Fab/Kev Sib Txuas Lus Qhia: 2 x IEC ntsaws / 1 x plug-in terminal block, 2-pin, tso zis phau ntawv lossis hloov pauv tau (siab tshaj 1 A, 24 V DC bzw. 24 V AC) Kev Tswj Xyuas Hauv Zos thiab Kev Hloov Khoom Siv...
-
Hirschmann GRS103-6TX/4C-1HV-2S hloov
Hnub Tim Muag Khoom Cov Lus Piav Qhia Txog Khoom Lub Npe: GRS103-6TX/4C-1HV-2S Software Version: HiOS 09.4.01 Hom Chaw Nres thiab Qhov Ntau: Tag Nrho 26 Chaw Nres, 4 x FE/GE TX/SFP thiab 6 x FE TX kho tau teeb tsa; ntawm Media Modules 16 x FE Ntau Qhov Sib Txuas Lus Fais Fab/Kev Sib Txuas Lus Qhia: 1 x IEC ntsaws / 1 x plug-in terminal block, 2-pin, tso zis phau ntawv lossis hloov pauv tau (siab tshaj 1 A, 24 V DC bzw. 24 V AC) Kev Tswj Xyuas Hauv Zos thiab Kev Hloov Khoom Siv...
-
Hirschmann MM3-4FXM2 Media Module Rau MICE Switch...
Kev piav qhia Cov lus piav qhia txog khoom Hom: MM3-4FXM2 Tus lej ntawm qhov chaw: 943764101 Muaj: Hnub kawg ntawm kev txiav txim: Lub Kaum Ob Hlis 31, 2023 Hom chaw nres nkoj thiab qhov ntau: 4 x 100Base-FX, MM cable, SC sockets Qhov loj ntawm lub network - qhov ntev ntawm cable Multimode fiber (MM) 50/125 µm: 0 - 5000 m, 8 dB txuas nyiaj txiag ntawm 1300 nm, A = 1 dB/km, 3 dB tseg, B = 800 MHz x km Multimode fiber (MM) 62.5/125 µm: 0 - 4000 m, 11 dB txuas nyiaj txiag ntawm 1300 nm, A = 1 dB/km, 3...


