• lub taub hau_chij_01

Hirschmann GRS105-16TX/14SFP-2HV-2A Hloov

Kev Piav Qhia Luv:

Cov GREYHOUND 105/106 switches 'kev tsim qauv yooj ywm ua rau qhov no yog lub cuab yeej networking yav tom ntej uas tuaj yeem hloov pauv nrog koj lub network bandwidth thiab lub zog xav tau. Nrog rau kev tsom mus rau qhov siab tshaj plaws network muaj nyob rau hauv cov xwm txheej kev lag luam, cov switches no tso cai rau koj xaiv lub cuab yeej lub chaw nres nkoj suav thiab hom - txawm tias muab lub peev xwm rau koj siv GREYHOUND 105/106 series ua lub pob txha hloov pauv.

 


Cov Lus Qhia Txog Khoom

Cov Cim Npe Khoom

Hnub Ua Lag Luam

 

Khoom piav qhia

Hom GRS105-16TX/14SFP-2HV-2A (Tus lej khoom: GRS105-6F8F16TSGGY9HHSE2A99XX.X.XX)
Kev piav qhia GREYHOUND 105/106 Series, Kev Tswj Xyuas Kev Lag Luam, tsim tsis muaj kiv cua, 19 "rack mount, raws li IEEE 802.3, 6x1/2.5GE +8xGE +16xGE Tsim
Cov Qauv Software HiOS 9.4.01
Tus lej khoom 942 287 005
Hom chaw nres nkoj thiab qhov ntau Tag nrho 30 Chaw nres nkoj, 6x GE/2.5GE SFP qhov + 8x GE SFP qhov + 16x FE/GE TX qhov chaw nres nkoj

 

Ntau ntxiv Cov kev sib txuas lus

Kev sib txuas lus fais fab / kev taw qhia  

Qhov chaw fais fab nkag 1: IEC ntsaws, Kev sib cuag teeb liab: 2 tus pin ntsaws rau hauv lub davhlau ya nyob twg, Qhov chaw fais fab nkag 2: IEC ntsaws

Qhov chaw rau daim npav SD 1 x SD daim npav qhov txuas rau lub adapter teeb tsa pib ACA31
USB-C 1 x USB-C (tus neeg siv khoom) rau kev tswj hwm hauv zos

 

Kev Sib Txuas Lus qhov loj - ntev of xov hlau

Twisted khub (TP) 0-100 m
Ib hom fiber (SM) 9/125 µm saib cov modules SFP
Ib hom fiber ntau (LH) 9/125 µm (transceiver ntev)  

saib cov modules SFP

Multimode fiber (MM) 50/125 µm saib cov modules SFP
Multimode fiber (MM) 62.5 / 125 µm saib cov modules SFP

 

Kev Sib Txuas Lus qhov loj - cascadibility

Kab - / lub hnub qub topology ib yam dab tsi

 

Lub zog cov kev cai

Kev Ua Haujlwm Voltage Lub zog fais fab nkag 1: 110 - 240 VAC, 50 Hz - 60 Hz, Lub zog fais fab nkag 2: 110 - 240 VAC, 50 Hz - 60 Hz
Kev siv hluav taws xob Chav yooj yim nrog ib lub zog fais fab siab tshaj 35W
Lub zog tso zis hauv BTU (IT) / teev siab tshaj 120

 

Cov software

 

 

Kev Hloov

Kev Kawm VLAN Ywj Pheej, Kev Laus Sai, Kev Nkag Chaw Nyob Unicast/Multicast Static, QoS / Port Prioritization (802.1D/p), TOS/DSCP Prioritization, Interface Trust Mode, CoS Queue Management, Queue-Shaping / Max. Queue Bandwidth, Flow Control (802.3X), Egress Interface Shaping, Ingress Storm Protection, Jumbo Frames, VLAN (802.1Q), VLAN Unaware Mode, GARP VLAN Registration Protocol (GVRP), Voice VLAN, GARP Multicast Registration Protocol (GMRP), IGMP Snooping/Querier ib VLAN (v1/v2/v3), Unknown Multicast Filtering, Multiple VLAN Registration Protocol (MVRP), Multiple MAC Registration Protocol (MMRP), Multiple Registration Protocol (MRP), IP Ingress DiffServ Classification and Policing, IP Egress DiffServ Classification and Policing, Protocol-based VLAN, MAC-based VLAN, IP subnet-based VLAN, Double VLAN Tagging
Kev Rov Ua Dua HIPER-Ring (Ring Switch), Link Aggregation nrog LACP, Link Backup, Media Redundancy Protocol (MRP) (IEC62439-2), RSTP 802.1D-2004 (IEC62439-1), RSTP Guards
Kev Tswj Xyuas Kev Txhawb Nqa Duab Software Ob Chav, TFTP, SFTP, SCP, LLDP (802.1AB), LLDP-MED, SSHv2, HTTP, HTTPS, Kev Tswj IPv6, Cov Ntxaib, SNMP v1/v2/v3, Telnet, DNS Client, OPC-UA Server

 

 

Kev kuaj mob

Kev Tshawb Pom Qhov Teeb Meem Tsis Sib Haum Xeeb ntawm Chaw Nyob Tswj, Kev Ceeb Toom MAC, Kev Sib Txuas Lus, Kev Qhia Txog Qhov Xwm Txheej ntawm Lub Tshuab, TCPDump, LEDs, Syslog, Kev Sau Npe Mus Ib Txhis ntawm ACA, Kev Saib Xyuas Chaw Nres Nkoj nrog Kev Tua Tsis Siv Neeg, Kev Tshawb Pom Qhov Txuas Ntawm Qhov Txuas, Kev Tshawb Pom Qhov Ntau Dhau, Kev Tshawb Pom Qhov Tsis Sib Haum Xeeb ntawm Duplex, Kev Saib Xyuas Qhov Ceev Ntawm Qhov Txuas thiab Duplex, RMON (1,2,3,9), Kev Tshawb Pom Qhov Txuas 1:1, Kev Tshawb Pom Qhov Txuas 8:1, Kev Tshawb Pom Qhov Txuas N:1, Kev Tshawb Pom Qhov Txuas N:2, Cov Ntaub Ntawv System, Kev Tshawb Xyuas Tus Kheej ntawm Kev Pib Txias, Kev Tshawb Pom Qhov Txuas Tooj Liab, Kev Tswj Xyuas SFP, Kev Tshawb Xyuas Kev Teeb Tsa, Kev Hloov Pauv, Kev Ceeb Toom Email, RSPAN, SFLOW, Kev Tshawb Pom VLAN
 

Kev teeb tsa

Tsis Siv Neeg Configuration Undo (roll-back), Configuration Fingerprint, Text-based Configuration File (XML), Backup config ntawm lub server nyob deb thaum txuag, Clear config tab sis khaws IP settings, BOOTP/DHCP Client nrog Auto-Configuration, DHCP Server: ib Port, DHCP Server: Pools ib VLAN, AutoConfiguration Adapter ACA31 (SD card), HiDiscovery, DHCP Relay nrog Option 82, Command Line Interface (CLI), CLI Scripting, CLI script handling hla ENVM thaum khau raj, Full-featured MIB Support, Context-sensitive Help, HTML5 based Management
 

 

Kev Ruaj Ntseg

Kev Ruaj Ntseg Chaw Nres Nkoj MAC, Kev Tswj Xyuas Kev Nkag Mus Rau Hauv Chaw Nres Nkoj nrog 802.1X, VLAN Qhua/tsis tau lees paub, Tus Neeg Pabcuam Kev Pom Zoo Ua Ke (IAS), RADIUS VLAN Assignment, Kev Tiv Thaiv Kev Tsis Kam Lees Paub Kev Pabcuam, ACL raws li VLAN, ACL raws li Ingress VLAN, ACL yooj yim, Kev Nkag Mus Rau Kev Tswj Xyuas uas txwv los ntawm VLAN, Kev Qhia Txog Kev Ruaj Ntseg ntawm Cov Khoom Siv, Txoj Kev Tshawb Xyuas, Kev Sau Npe CLI, Kev Tswj Xyuas Daim Ntawv Pov Thawj HTTPS, Kev Nkag Mus Rau Kev Tswj Xyuas Txwv, Daim Ntawv Qhia Siv Tsim Nyog, Txoj Cai Password uas Kho Tau, Tus lej ntawm Kev Sim Nkag Mus Rau Hauv, Kev Sau Npe SNMP, Ntau Qib Kev Tso Cai, Kev Tswj Xyuas Tus Neeg Siv Hauv Zos, Kev Pom Zoo Los Ntawm Chaw Deb Ntawm RADIUS, Kev Xauv Tus Neeg Siv Account, Hloov Password thaum nkag mus thawj zaug, Kev Muab Txoj Cai RADIUS, Kev Pom Zoo Ntau Tus Neeg Siv Khoom Ib Chaw Nres Nkoj, Kev Hloov Pauv MAC, Kev Xaiv Hom Ntawv rau Kev Hloov Pauv MAC, DHCP Snooping, IP Source Guard, Dynamic ARP Inspection, LDAP, Ingress MAC-based ACL, Egress MAC-based ACL, Ingress IPv4-based ACL, Egress IPv4-based ACL, Time-based ACL, Egress VLAN-raws li ACL, ACL Flow-raws li kev txwv
Kev sib dhos sijhawm PTPv2 Lub Moos Pob Kaj Ob Kauj Ruam, PTPv2 Lub Moos Ciam Teb, BC nrog Txog Li 8 Sync / s, Buffered Real Time Clock, SNTP Client, SNTP Server
Cov Ntaub Ntawv Kev Lag Luam EtherNet/IP Protocol Modbus TCP PROFINET Protocol
Lwm yam Kev Hla Cable Tes, Chaw Nres Nkoj Fais Fab

 

Cov xwm txheej ib puag ncig

Kub ua haujlwm -10 - +60
Lus Cim 1 013 941
Kub cia / thauj mus los -20 - +70 °C
Qhov av noo (tsis-condensing) 5-90%

 

Kev tsim kho tshuab

Qhov Loj (WxHxD) 444 x 44 x 355 hli
Qhov hnyav Kwv yees li ntawm 5 kg
Kev Teeb Tsa Rack mount
Chav kawm tiv thaiv IP30

 

Cov Qauv Muaj ntawm Hirschmann GRS 105 106 Series GREYHOUND Switch

GRS105-16TX/14SFP-2HV-3AUR

GRS105-24TX/6SFP-1HV-2A

GRS105-24TX/6SFP-2HV-2A

GRS105-24TX/6SFP-2HV-3AUR

GRS106-16TX/14SFP-1HV-2A

GRS106-16TX/14SFP-2HV-2A

GRS106-16TX/14SFP-2HV-3AUR

GRS106-24TX/6SFP-1HV-2A

GRS106-24TX/6SFP-2HV-2A

GRS106-24TX/6SFP-2HV-3AUR

 


  • Yav dhau los:
  • Tom ntej no:

  • Sau koj cov lus ntawm no thiab xa tuaj rau peb

    Cov khoom cuam tshuam

    • Hirschmann RS20-1600T1T1SDAPHH Kev Hloov Kho uas Tswj tau

      Hirschmann RS20-1600T1T1SDAPHH Kev Hloov Kho uas Tswj tau

      Kev Piav Qhia Khoom: Hirschmann Hirschmann RS20-1600T1T1SDAPHH Configurator: RS20-1600T1T1SDAPHH Kev Piav Qhia Khoom Kev Piav Qhia Tswj Fast-Ethernet-Switch rau DIN rail khw-thiab-mus tom ntej-switching, tsim tsis muaj kiv cua; Software Layer 2 Professional Part Number 943434022 Hom chaw nres nkoj thiab ntau npaum li cas 8 chaw nres nkoj tag nrho: 6 x tus qauv 10/100 BASE TX, RJ45; Uplink 1: 1 x 10/100BASE-TX, RJ45; Uplink 2: 1 x 10/100BASE-TX, RJ45; Uplink 2: 1 x 10/100BASE-TX, R...

    • Hirschmann BRS40-00209999-STCZ99HHSES Hloov

      Hirschmann BRS40-00209999-STCZ99HHSES Hloov

      Hnub Tim Muag Khoom Piav Qhia Txog Khoom Piav Qhia Kev Tswj Xyuas Kev Lag Luam rau DIN Rail, tsim tsis muaj kiv cua Txhua hom Gigabit Software Version HiOS 09.6.00 Hom chaw nres nkoj thiab ntau npaum li cas 20 Chaw nres nkoj tag nrho: 20x 10/100/1000BASE TX / RJ45 Ntau qhov sib txuas Lub zog muab hluav taws xob / kev sib txuas lus 1 x plug-in terminal block, 6-pin Digital Input 1 x plug-in terminal block, 2-pin Local Management thiab Device Replacement USB-C ...

    • Hirschmann GRS105-24TX/6SFP-2HV-2A hloov

      Hirschmann GRS105-24TX/6SFP-2HV-2A hloov

      Hnub Tim Muag Khoom Cov Lus Piav Qhia Txog Khoom Hom GRS105-24TX/6SFP-2HV-2A (Khoom code: GRS105-6F8T16TSGGY9HHSE2A99XX.X.XX) Kev Piav Qhia GREYHOUND 105/106 Series, Managed Industrial Switch, tsim tsis muaj kiv cua, 19" rack mount, raws li IEEE 802.3, 6x1/2.5GE +8xGE +16xGE Design Software Version HiOS 9.4.01 Tus lej seem 942 287 002 Hom chaw nres nkoj thiab ntau npaum li cas 30 Chaw nres nkoj tag nrho, 6x GE/2.5GE SFP qhov + 8x FE/GE TX chaw nres nkoj + 16x FE/GE TX po...

    • HIRSCHMANN BRS30-1604OOOO-STCZ99HHSES KEV TSWJ HWM

      HIRSCHMANN BRS30-1604OOOO-STCZ99HHSES TSWJ S...

      Hnub Tim Ua Lag Luam HIRSCHMANN BRS30 Series Cov Qauv Muaj BRS30-0804OOOO-STCZ99HHSESXX.X.XX BRS30-1604OOOO-STCZ99HHSESXX.X.XX BRS30-2004OOOO-STCZ99HHSESXX.X.XX

    • Hirschmann SPR20-8TX-EEC Unmanaged Switch

      Hirschmann SPR20-8TX-EEC Unmanaged Switch

      Hnub Tim Muag Khoom Piav Qhia Txog Khoom Piav Qhia Tsis Muaj Kev Tswj, Kev Lag Luam ETHERNET Rail Switch, tsim tsis muaj kiv cua, khaws cia thiab hloov mus tom ntej hom, USB interface rau kev teeb tsa, Fast Ethernet Port hom thiab ntau npaum li cas 8 x 10/100BASE-TX, TP cable, RJ45 sockets, auto-crossing, auto-negotiation, auto-polarity Ntau Interfaces Fais fab mov / signaling tiv tauj 1 x plug-in terminal block, 6-pin USB interface 1 x USB rau configura...

    • Hirschmann MIPP/AD/1L1P Modular Industrial Patch Panel configurator

      Hirschmann MIPP/AD/1L1P Modular Industrial Patc...

      Cov Lus Qhia Txog Khoom Khoom: MIPP/AD/1L1P Tus Neeg Teeb tsa: MIPP - Modular Industrial Patch Panel configurator Cov Lus Qhia Txog Khoom MIPP™ yog ib lub vaj huam sib luag rau kev lag luam uas ua rau cov xov hlau raug teeb tsa thiab txuas nrog cov khoom siv xws li cov hloov pauv. Nws cov qauv tsim muaj zog tiv thaiv kev sib txuas hauv yuav luag txhua daim ntawv thov kev lag luam. MIPP™ los ua ib lub thawv Fiber Splice, Copper Patch Panel, lossis ib lub...